In the searchlight Matej Znidaric works closely with Bence György in establishing one of the first optogenetic therapy models for the treatment of retinitis pigmentosa, an eye disease that affects cone photoreceptor cells and can lead to blindness. Text by Goran Mijuk, photos and videos by Laurids Jensen.
When Matej Znidaric is working with retina samples and exposing them to light impulses in the IOB physiology lab, he does this in almost complete darkness. Only a red light provides him with guidance.
Znidaric works both with human and animal retina samples. He receives human eye samples from partner hospitals in Budapest and Basel.
A trained physiologist and biologist, he prepares the tissue samples by cutting the retina into tiny pieces before measuring the behavior of genetically altered cone photoreceptor cells under artificial light conditions.
Before the measurements can start, the cone photoreceptors in the retina, which degenerate in certain diseases, are treated with special light-sensing proteins that are induced through a viral vector.
The light-sensing proteins, which take four to five weeks to express in tissue, can capture light and send these impulses to other retina cells. These cells then transfer the signals to ganglion cells, which connect the retina with the brain.
Znidaric uses highly specialized tools for his delicate sample preparation.
What for non-experts may look like a microscope because of the visible eyepieces is in fact a bespoke sensor apparatus that allows for extensive and exact cell behavior testing.
Znidaric has designed and assembled the apparatus himself, using devices such as chips and software from several third-party providers.
The front includes an array of instruments that help keep the sample tissues alive, register voltage changes, and connect these electric signals to a software.
The light projector (shown in the picture is a new version that is currently not in use) is installed in the back of the apparatus.
To keep the samples alive while the experiment runs, the retina samples receive nutrients and oxygen.
The flow rate, with the outflow managed by a pump, is at a constant 4 to 5 milliliters per minute.
The pieces of a cut retina are stored in six-well culture plates, where they are attached to a thin membrane. The tissue samples are kept in these wells for four to six weeks, during which time their medium is regularly changed.
Once Znidaric starts with the experiment, he takes the samples from the wells, detaches them from the membranes and transfers them to a chip. On the chip the samples get “covered” by a metal harp with thin wires to hold the tissue in place.
The microelectrode array constitutes the core of the apparatus. It is a sensor with electrodes. The array currently used by Znidaric (shown in the picture through the microscope under red light) is equipped with 16 x 16 electrodes, each spaced 100 micrometers apart. The IOB is also using arrays developed by the ETH (green chip), which has 25,000 electrodes.
For the measurement, the cone photoreceptor cells, which lie on top of the tissue, receive the light impulses directly. From there, the signal travels through a cascade of cells in the retina until it reaches the ganglion cells at the bottom of the tissue.
As part of this process, the ganglion cells change their membrane potential, which results in a change of voltage registered by the electrodes. The electrodes then transmit the signal to the computer.
The setup of an experiment is complex and data-intensive. One computational line registers the light impulses, while the other identifies the electric transmission from the electrodes. Both lines need to be aligned in time to have a correct data read-out.
The process needs to run with the maximum possible precision given that the time difference between the light impulses and the voltage changes in the ganglion membrane is counted in milliseconds. The amount of data coming from a single experiment can easily reach a terabyte.
The software registers the voltage change in the ganglion cells. The sensor fields of the chip are represented as a grid on the screen. Matej Znidaric needs to establish how many of the retina cells respond to light stimulation and what the response properties are. If the ganglion cells show a spiking behavior on the screen, it means that they are receiving impulses from the “rescued” photoreceptor cells and that the retina is once again able to process light.
In a potential optogenetic therapy, this means that a person can have their vision restored. After the experiment, the retina samples are stained with a fluorescent protein to identify the cone photoreceptors. The team at the IOB also takes high-resolution images with the help of a spinning disk confocal microscope.